NON-INVASIVE NEONATAL BILIRUBINOMETER
BILICARE
Accurate measurement and control of bilirubin levels
The BiliCare transcutaneous bilirubinometer measures bilirubin levels precisely and reliably using its patented LED technology.
The measurement is taken in the hem of the ear, the scaphoid, by simple contact with the LED reading clip. The measurement method and angle are thus standardized, which allows precise results to be obtained.
The BiliCare sends light at precise wavelengths through the skin and, by measuring the absorption by bilirubin, it deduces the bilirubinemia value.
- Fast
- Specific
- Practical
Technical characteristics
Speed and convenience
- Transcutaneous measurement: reduces the number of blood samples taken by heel puncture.
- Possibility of averages on 2 or 3 measurements.
- Large and clear display for good visibility.
- Touch screen usable with or without gloves.
- Easy and ergonomic user interface.
- Memory of up to 40 measurements making it easy to transcribe and compare results.
- Patient and practitioner identification by barcode or manual entry.
- Easy cleaning and disinfection of the tip
Accuracy
- BiliCare has been validated in clinical studies to provide results comparable to blood tests.
Repeatability tests confirm reliable results (technical data on request).
Convenience
- The BiliCare system can work with or without a disposable button cover.
- LEDs do not require routine calibration, minimizing maintenance and associated costs.
- Long-lasting rechargeable battery with holder allows for extended use and easy recharging.
Technical specifics
- Gestational age: > 24 weeks
- Suitable for all skin types
- Measuring range: 0-20 mg/dL – 0-340 μmol/L
- Correlation: r=0,90
- Reproductivity (SD*): ± 0,7 mg/dL – ± 12 μmol/L
- Accuracy (RMSE*): ± 1,5 mg/dL – ± 26 μmol/L in 66% of cases
- Barcode reader
- LED light source: lifespan > 200 measurements
- PC connectivity: USB
- Hospital IT service connectivity: HL7 protocol
- Charging station provided
- Maximum charging time: 4 hours
- Weight with battery: 160 g
*SD: Standard Deviation, RMSE: Root Mean Square Error
Manufacturer: Gerium Medical Ltd
Class: Im
EC 0483
Read the instructions in the package leaflet or on the label carefully.
Medical device not reimbursed by social security
Updated: 03/06/2024
Supporting videos
References and packaging
- 81000300 | BiliCare bilirubinometer
- 81000200 | BiliCare complete set with accessories
- 37000130 | Single-use BiliCare hygienic sensor covers | 60 units
- 37000131 | Single-use BiliCare hygienic sensor covers | 600 units
- 38000110 | Calibration Verification Accessories | 3 units
Related products

Collection for Guthrie Tenderfoot test

Bilirubinometer KJ-8000
